All MIBs › ADVA-FSPR7-PM-MIB › gfpfrFacilityCurrent1dayCHecDiscardedFrames
gfpfrFacilityCurrent1dayCHecDiscardedFrames
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Core HEC Discarded Frames
What is gfpfrFacilityCurrent1dayCHecDiscardedFrames?
This 24-hour counter tracks cumulative frame discards due to Core HEC violations, showing degradation trends over the entire day. Operators monitoring this metric can detect intermittent optical layer problems that accumulate over time even if individual intervals appear normal. An example value of 89 discarded frames over 24 hours suggests occasional bit errors from fiber transmission impairments.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.107 | gfpfrFacilityCurrent1dayTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1 | gfpfrFacilityCurrent1dayEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2 | gfpfrFacilityCurrent1dayCHecDiscardedFrames | ADVA-FSPR7-PM-MIB |