ADVA-FSPR7-PM-MIB :: gfpfrFacilityCurrent1dayCHecDiscardedFrames

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBgfpfrFacilityCurrent1dayCHecDiscardedFrames

gfpfrFacilityCurrent1dayCHecDiscardedFrames

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Core HEC Discarded Frames

What is gfpfrFacilityCurrent1dayCHecDiscardedFrames?

This 24-hour counter tracks cumulative frame discards due to Core HEC violations, showing degradation trends over the entire day. Operators monitoring this metric can detect intermittent optical layer problems that accumulate over time even if individual intervals appear normal. An example value of 89 discarded frames over 24 hours suggests occasional bit errors from fiber transmission impairments.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayCHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.107gfpfrFacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1gfpfrFacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.2gfpfrFacilityCurrent1dayCHecDiscardedFramesADVA-FSPR7-PM-MIB