ADVA-FSPR7-PM-MIB :: gfpfrFacilityCurrent15minTHecDiscardedFrames

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBgfpfrFacilityCurrent15minTHecDiscardedFrames

gfpfrFacilityCurrent15minTHecDiscardedFrames

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Type Field HEC Discarded Frames

What is gfpfrFacilityCurrent15minTHecDiscardedFrames?

This counter accumulates frames discarded in the current 15-minute period due to Type Field HEC (Header Error Control) checksum failures in GFP payload sections. Type field errors indicate corruption of the frame classification information, making it impossible to route the payload correctly. An example value of 5 discarded frames indicates occasional payload header corruption on the monitored facility.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.105gfpfrFacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1gfpfrFacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3gfpfrFacilityCurrent15minTHecDiscardedFramesADVA-FSPR7-PM-MIB