All MIBs › ADVA-FSPR7-PM-MIB › gfpfrFacilityCurrent15minTHecDiscardedFrames
gfpfrFacilityCurrent15minTHecDiscardedFrames
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Type Field HEC Discarded Frames
What is gfpfrFacilityCurrent15minTHecDiscardedFrames?
This counter accumulates frames discarded in the current 15-minute period due to Type Field HEC (Header Error Control) checksum failures in GFP payload sections. Type field errors indicate corruption of the frame classification information, making it impossible to route the payload correctly. An example value of 5 discarded frames indicates occasional payload header corruption on the monitored facility.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent15minTHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.105 | gfpfrFacilityCurrent15minTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1 | gfpfrFacilityCurrent15minEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.105.1.3 | gfpfrFacilityCurrent15minTHecDiscardedFrames | ADVA-FSPR7-PM-MIB |