All MIBs › ADVA-FSPR7-PM-MIB › frTrmt2FacilityHistorical15minCrcFramesEgress
frTrmt2FacilityHistorical15minCrcFramesEgress
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::frTrmt2FacilityHistorical15minCrcFramesEgress
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.213.1.5
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Egress CRC Errored Frames
What is frTrmt2FacilityHistorical15minCrcFramesEgress?
Reports an unsigned integer counter of frames with cyclic redundancy check (CRC) errors detected at the egress during 15-minute buckets. Identifies physical-layer transmission errors indicating cable quality, interface, or serialization issues. Example value: 23 CRC-errored frames.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.213.1.5 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frTrmt2FacilityHistorical15minCrcFramesEgress
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.213.1.5.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frTrmt2FacilityHistorical15minCrcFramesEgress.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frTrmt2FacilityHistorical15minCrcFramesEgress OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.213 | frTrmt2FacilityHistorical15minTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.213.1 | frTrmt2FacilityHistorical15minEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.213.1.5 | frTrmt2FacilityHistorical15minCrcFramesEgress | ADVA-FSPR7-PM-MIB |