ADVA-FSPR7-PM-MIB :: frTrmt1FacilityHistorical15minCrcFramesEgress

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrTrmt1FacilityHistorical15minCrcFramesEgress

frTrmt1FacilityHistorical15minCrcFramesEgress

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frTrmt1FacilityHistorical15minCrcFramesEgress

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.189.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Egress CRC Errored Frames

What is frTrmt1FacilityHistorical15minCrcFramesEgress?

Reports the count of frames with cyclic redundancy check errors detected on egress (outbound) transmit. CRC errors indicate physical layer corruption or cable quality issues, and elevated counts suggest signal integrity problems requiring hardware investigation. An example value of 12 CRC errors over 15 minutes warrants attention to fiber connections or transceiver health.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.189.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frTrmt1FacilityHistorical15minCrcFramesEgress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.189.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frTrmt1FacilityHistorical15minCrcFramesEgress.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frTrmt1FacilityHistorical15minCrcFramesEgress OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.189frTrmt1FacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.189.1frTrmt1FacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.189.1.5frTrmt1FacilityHistorical15minCrcFramesEgressADVA-FSPR7-PM-MIB