ADVA-FSPR7-PM-MIB :: frTrmt1FacilityCurrent15minCrcFramesEgress

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrTrmt1FacilityCurrent15minCrcFramesEgress

frTrmt1FacilityCurrent15minCrcFramesEgress

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frTrmt1FacilityCurrent15minCrcFramesEgress

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.185.1.4

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Egress CRC Errored Frames

What is frTrmt1FacilityCurrent15minCrcFramesEgress?

This counter reports the count of frames with CRC errors detected on the egress (outbound) direction of the Ethernet facility during the current 15-minute period. Egress CRC errors indicate data corruption occurring as frames leave the facility; this metric is critical for identifying transmit-path quality issues. A typical threshold alert might trigger on 10 egress CRC errors in 15 minutes, signaling hardware degradation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.185.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frTrmt1FacilityCurrent15minCrcFramesEgress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.185.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frTrmt1FacilityCurrent15minCrcFramesEgress.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frTrmt1FacilityCurrent15minCrcFramesEgress OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.185frTrmt1FacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.185.1frTrmt1FacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.185.1.4frTrmt1FacilityCurrent15minCrcFramesEgressADVA-FSPR7-PM-MIB