ADVA-FSPR7-PM-MIB :: frRcv3FacilityHistorical1dayOversizedFramesRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrRcv3FacilityHistorical1dayOversizedFramesRcv

frRcv3FacilityHistorical1dayOversizedFramesRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayOversizedFramesRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.9

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Oversized Frames Received

What is frRcv3FacilityHistorical1dayOversizedFramesRcv?

This counter measures frames exceeding the standard Ethernet limit (>1518 bytes non-jumbo) received during a 24-hour window as a 64-bit value. Oversized frames can indicate jumbo frame support, MTU misconfiguration, or frame corruption requiring network investigation. A daily total of 89342 oversized frames would suggest consistent jumbo frame usage or configuration inconsistencies.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.9
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayOversizedFramesRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.9.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayOversizedFramesRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayOversizedFramesRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167frRcv3FacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1frRcv3FacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.9frRcv3FacilityHistorical1dayOversizedFramesRcvADVA-FSPR7-PM-MIB