ADVA-FSPR7-PM-MIB :: frRcv3FacilityHistorical1dayBytesFrames128Rcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrRcv3FacilityHistorical1dayBytesFrames128Rcv

frRcv3FacilityHistorical1dayBytesFrames128Rcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBytesFrames128Rcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.15

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: 128-255 Byte Frames Received

What is frRcv3FacilityHistorical1dayBytesFrames128Rcv?

This OID reports the count of frames sized between 128 and 255 bytes received daily as a counter value. Monitoring this range helps identify applications using small to medium packets, which can reveal suboptimal batching or fragmentation issues. A concrete example is 24000 frames tallied over a 24-hour period.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.15
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBytesFrames128Rcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.15.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBytesFrames128Rcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBytesFrames128Rcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167frRcv3FacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1frRcv3FacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.15frRcv3FacilityHistorical1dayBytesFrames128RcvADVA-FSPR7-PM-MIB