frRcv3FacilityHistorical1dayBroadcastFramesRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBroadcastFramesRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.6

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Broadcast Frames Received

What is frRcv3FacilityHistorical1dayBroadcastFramesRcv?

This OID counts broadcast frames (destination MAC FF:FF:FF:FF:FF:FF) received during a 24-hour period as a 64-bit value. Broadcast frame monitoring helps detect excessive ARP requests, DHCP traffic, or network storms that could degrade performance. A typical daily count might be 342156 broadcast frames, indicating normal ARP and discovery protocol activity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBroadcastFramesRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBroadcastFramesRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv3FacilityHistorical1dayBroadcastFramesRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167frRcv3FacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1frRcv3FacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.167.1.6frRcv3FacilityHistorical1dayBroadcastFramesRcvADVA-FSPR7-PM-MIB