ADVA-FSPR7-PM-MIB :: frRcv3FacilityCurrent1dayJabberFrameRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrRcv3FacilityCurrent1dayJabberFrameRcv

frRcv3FacilityCurrent1dayJabberFrameRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayJabberFrameRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.10

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Rx Jabber Frame

What is frRcv3FacilityCurrent1dayJabberFrameRcv?

This counter tracks the number of jabber frames (excessively long frames caused by hardware failures) received during the current calendar day as a 64-bit unsigned integer. Jabber detection indicates serious physical layer defects requiring hardware replacement. An example value is 15 jabber frames indicating an intermittent transmitter fault on the sending equipment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.10
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayJabberFrameRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.10.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayJabberFrameRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayJabberFrameRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.163frRcv3FacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1frRcv3FacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.10frRcv3FacilityCurrent1dayJabberFrameRcvADVA-FSPR7-PM-MIB