ADVA-FSPR7-PM-MIB :: frRcv3FacilityCurrent1dayBroadcastFramesRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrRcv3FacilityCurrent1dayBroadcastFramesRcv

frRcv3FacilityCurrent1dayBroadcastFramesRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayBroadcastFramesRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Broadcast Frames Received

What is frRcv3FacilityCurrent1dayBroadcastFramesRcv?

This counter tracks the number of broadcast frames (destination MAC FF:FF:FF:FF:FF:FF) received during the current calendar day as a 64-bit unsigned integer. Abnormally high broadcast counts can indicate broadcast storms or network misconfiguration affecting overall performance. An example value is 3,250,000 broadcast frames in a 24-hour period representing normal ARP and DHCP traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayBroadcastFramesRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayBroadcastFramesRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent1dayBroadcastFramesRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.163frRcv3FacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1frRcv3FacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.163.1.5frRcv3FacilityCurrent1dayBroadcastFramesRcvADVA-FSPR7-PM-MIB