ADVA-FSPR7-PM-MIB :: frRcv3FacilityCurrent15minBroadcastFramesRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrRcv3FacilityCurrent15minBroadcastFramesRcv

frRcv3FacilityCurrent15minBroadcastFramesRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent15minBroadcastFramesRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.161.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Broadcast Frames Received

What is frRcv3FacilityCurrent15minBroadcastFramesRcv?

Reports a counter of broadcast frames (destination MAC = FF:FF:FF:FF:FF:FF) received during the current 15-minute interval. Broadcast traffic counts help operators identify broadcast storms, network loops, or ARP flooding events; excessive broadcast frames consume bandwidth and degrade switch performance. An example value would be 4521 broadcast frames received in the current 15-minute window.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.161.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent15minBroadcastFramesRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.161.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent15minBroadcastFramesRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv3FacilityCurrent15minBroadcastFramesRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.161frRcv3FacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.161.1frRcv3FacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.161.1.5frRcv3FacilityCurrent15minBroadcastFramesRcvADVA-FSPR7-PM-MIB