ADVA-FSPR7-PM-MIB :: frRcv2FacilityHistorical15minBytes

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfrRcv2FacilityHistorical15minBytes

frRcv2FacilityHistorical15minBytes

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv2FacilityHistorical15minBytes

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.157.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Bytes Received

What is frRcv2FacilityHistorical15minBytes?

This object preserves byte/octet count data from past 15-minute measurement periods on facility 2, enabling historical throughput reconstruction and capacity trend analysis. Archived 15-minute byte counts allow calculation of average bandwidth utilization patterns across specific hours or days. A historical entry of 281,100,000,000 bytes represents the data volume transferred during a specific 15-minute slot in the past.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.157.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv2FacilityHistorical15minBytes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.157.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv2FacilityHistorical15minBytes.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv2FacilityHistorical15minBytes OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.157frRcv2FacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.157.1frRcv2FacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.157.1.5frRcv2FacilityHistorical15minBytesADVA-FSPR7-PM-MIB