All MIBs › ADVA-FSPR7-PM-MIB › frRcv1FacilityCurrent15minDiscardedFrames
frRcv1FacilityCurrent15minDiscardedFrames
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::frRcv1FacilityCurrent15minDiscardedFrames
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.145.1.4
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Received Frames Discarded
What is frRcv1FacilityCurrent15minDiscardedFrames?
This OID counts frames received but intentionally discarded due to buffer exhaustion, policy filters, or CRC failures in the current 15-minute window. High discard rates signal dropped traffic and packet loss, impacting application reliability. Example values: 0 on healthy links, 5000 during congestion, 50000 if buffers are undersized.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.145.1.4 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv1FacilityCurrent15minDiscardedFrames
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.145.1.4.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::frRcv1FacilityCurrent15minDiscardedFrames.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::frRcv1FacilityCurrent15minDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.145 | frRcv1FacilityCurrent15minTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.145.1 | frRcv1FacilityCurrent15minEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.145.1.4 | frRcv1FacilityCurrent15minDiscardedFrames | ADVA-FSPR7-PM-MIB |