ADVA-FSPR7-PM-MIB :: fecFacilityHistorical1daySES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfecFacilityHistorical1daySES

fecFacilityHistorical1daySES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::fecFacilityHistorical1daySES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Severely Errored Seconds FEC Monitoring for internal use

What is fecFacilityHistorical1daySES?

This OID reports a counter value representing the number of severely errored seconds accumulated over a 24-hour historical interval on an OTU circuit protected by Forward Error Correction. In network monitoring, SES indicates periods where signal quality degraded below acceptable thresholds despite FEC protection, triggering alarm conditions when threshold limits are exceeded. A typical value might be 3, meaning 3 seconds out of the 24-hour period experienced severe errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::fecFacilityHistorical1daySES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::fecFacilityHistorical1daySES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::fecFacilityHistorical1daySES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55fecFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1fecFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.2fecFacilityHistorical1daySESADVA-FSPR7-PM-MIB