ADVA-FSPR7-PM-MIB :: fecFacilityHistorical1dayCE

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfecFacilityHistorical1dayCE

fecFacilityHistorical1dayCE

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayCE

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.3

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: OTU FEC Corrected Errors

What is fecFacilityHistorical1dayCE?

This OID reports a counter of bit errors that were successfully corrected by the FEC decoder within the 24-hour historical period, measured in corrected bit blocks. In network monitoring, this metric validates FEC effectiveness and identifies channels with marginal signal quality that are being rescued by forward error correction rather than failing. An example value might be 1542, indicating 1,542 corrected error blocks recovered over the day.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayCE

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayCE.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> fecFacilityHistorical1dayCE.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayCE OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55fecFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1fecFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.3fecFacilityHistorical1dayCEADVA-FSPR7-PM-MIB