ADVA-FSPR7-PM-MIB :: fecFacilityHistorical1dayBERCE

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfecFacilityHistorical1dayBERCE

fecFacilityHistorical1dayBERCE

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayBERCE

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Bit Error Rate before Foward Error Correction (FEC) calculated from corrected errors

What is fecFacilityHistorical1dayBERCE?

This OID reports the calculated bit error rate (BER) before FEC correction, expressed as a fractional value derived from the corrected error count and elapsed transmission time over the 24-hour period. In network monitoring, this BER metric quantifies raw channel quality before FEC intervention and predicts how quickly the circuit will degrade if FEC margins shrink. An example value might be 1.2e-9, representing 1.2 errors per 1 billion bits transmitted.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayBERCE

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayBERCE.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::fecFacilityHistorical1dayBERCE OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55fecFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1fecFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.55.1.5fecFacilityHistorical1dayBERCEADVA-FSPR7-PM-MIB