All MIBs › ADVA-FSPR7-PM-MIB › facilityPhysInstValuePrbsMaxBER
facilityPhysInstValuePrbsMaxBER
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsMaxBER
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.5
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Maximum measured BER for the PRBS Test signal during monitored time
What is facilityPhysInstValuePrbsMaxBER?
Reports the maximum bit error rate measured during Pseudo-Random Binary Sequence test signal monitoring, expressed as a ratio or exponent (e.g., 1e-10). This metric is valuable for diagnostic testing to assess link quality under controlled test patterns and identify signal integrity issues. A typical maximum BER value might be 1.2e-10 indicating good signal quality.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.5 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsMaxBER
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.5.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsMaxBER.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> facilityPhysInstValuePrbsMaxBER.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsMaxBER OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2 | pmFacilityPhysical | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1 | pmFacilityPhysValue | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1.1 | facilityPhysInstValueTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1 | facilityPhysInstValueEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.5 | facilityPhysInstValuePrbsMaxBER | ADVA-FSPR7-PM-MIB |