All MIBs › ADVA-FSPR7-PM-MIB › facilityPhysInstValuePrbsElapsedTime
facilityPhysInstValuePrbsElapsedTime
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsElapsedTime
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.8
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: Time elapsed since PRBS test monitoring started - reset
What is facilityPhysInstValuePrbsElapsedTime?
Reports the elapsed time since PRBS test monitoring was started or last reset, measured in seconds or time units. This counter helps operators understand the duration of diagnostic testing and when results were last initialized for trend analysis. A typical value might be 3600 seconds indicating one hour of test duration.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.8 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsElapsedTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.8.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsElapsedTime.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityPhysInstValuePrbsElapsedTime OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2 | pmFacilityPhysical | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1 | pmFacilityPhysValue | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1.1 | facilityPhysInstValueTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1 | facilityPhysInstValueEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.8 | facilityPhysInstValuePrbsElapsedTime | ADVA-FSPR7-PM-MIB |