ADVA-FSPR7-PM-MIB :: facilityPhysInstValueLaserBiasCurrentNormalized

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityPhysInstValueLaserBiasCurrentNormalized

facilityPhysInstValueLaserBiasCurrentNormalized

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityPhysInstValueLaserBiasCurrentNormalized

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.18

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Instantaneous Laser Bias Current Normalized

What is facilityPhysInstValueLaserBiasCurrentNormalized?

Reports the instantaneous laser bias current as a normalized percentage or ratio relative to maximum rated current. Normalized bias current provides a relative health indicator for trend analysis without absolute calibration, allowing operators to track aging patterns. A typical normalized value might be 78 percent indicating healthy laser operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.18
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValueLaserBiasCurrentNormalized

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.18.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValueLaserBiasCurrentNormalized.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityPhysInstValueLaserBiasCurrentNormalized OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1pmFacilityPhysValueADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1facilityPhysInstValueTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1facilityPhysInstValueEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.18facilityPhysInstValueLaserBiasCurrentNormalizedADVA-FSPR7-PM-MIB