ADVA-FSPR7-PM-MIB :: facilityPhysInstValueDifferentialGroupDelay

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityPhysInstValueDifferentialGroupDelay

facilityPhysInstValueDifferentialGroupDelay

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityPhysInstValueDifferentialGroupDelay

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.17

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Differential Group Delay measured and compensated by the module

What is facilityPhysInstValueDifferentialGroupDelay?

Reports the differential group delay (polarization-mode dispersion) measured and compensated by the module, expressed in picoseconds. DGD monitoring is essential in high-speed coherent systems to track chromatic impairments and verify that dispersion compensation is functioning properly. An example value might be 15.8 picoseconds indicating manageable polarization effects.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.17
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValueDifferentialGroupDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.17.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValueDifferentialGroupDelay.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityPhysInstValueDifferentialGroupDelay OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1pmFacilityPhysValueADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1facilityPhysInstValueTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1facilityPhysInstValueEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.17facilityPhysInstValueDifferentialGroupDelayADVA-FSPR7-PM-MIB