ADVA-FSPR7-PM-MIB :: facilityPhysInstValueCarrierFreqOffset

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityPhysInstValueCarrierFreqOffset

facilityPhysInstValueCarrierFreqOffset

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityPhysInstValueCarrierFreqOffset

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.15

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Carrier Frequency Offset

What is facilityPhysInstValueCarrierFreqOffset?

Reports the frequency offset of the detected carrier from the expected center frequency, measured in MHz or Hz. Carrier frequency offset is a critical parameter for coherent receiver synchronization; excessive offsets indicate tuning errors or temperature drift. An example value might be 45 MHz indicating a significant frequency deviation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.15
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValueCarrierFreqOffset

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.15.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityPhysInstValueCarrierFreqOffset.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityPhysInstValueCarrierFreqOffset OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1pmFacilityPhysValueADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1facilityPhysInstValueTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1facilityPhysInstValueEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.1.1.1.15facilityPhysInstValueCarrierFreqOffsetADVA-FSPR7-PM-MIB