ADVA-FSPR7-PM-MIB :: facilityDataThresholdSESOtuHT1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityDataThresholdSESOtuHT1day

facilityDataThresholdSESOtuHT1day

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.36

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: OTU Severely Errored Seconds 1 Day Threshold

What is facilityDataThresholdSESOtuHT1day?

Reports an unsigned integer representing the maximum number of Severely Errored Seconds permitted on an OTU circuit during a 24-hour collection window. This threshold triggers alarms when optical transport unit quality severely degrades, indicating potential fiber damage or equipment malfunction. A typical threshold value is 10 severely errored seconds per day.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.36
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.36.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT1day.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.36.1 i <value>

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT1day OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.36facilityDataThresholdSESOtuHT1dayADVA-FSPR7-PM-MIB