ADVA-FSPR7-PM-MIB :: facilityDataThresholdSESOtuHT15min

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityDataThresholdSESOtuHT15min

facilityDataThresholdSESOtuHT15min

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.35

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: OTU Severely Errored Seconds 15 Minute Threshold

What is facilityDataThresholdSESOtuHT15min?

This OID holds an unsigned integer threshold for severely errored seconds at the OTU interface measured over 15 minutes. Severe OTU-layer errors indicate the optical signal is critically degraded and at immediate risk of complete path failure, demanding urgent physical layer investigation. A threshold of 1-2 seconds ensures operators respond to even brief periods of critical optical degradation before complete signal loss occurs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.35
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.35.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT15min.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.35.1 i <value>

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOtuHT15min OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.35facilityDataThresholdSESOtuHT15minADVA-FSPR7-PM-MIB