ADVA-FSPR7-PM-MIB :: facilityDataThresholdSESOduHT1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityDataThresholdSESOduHT1day

facilityDataThresholdSESOduHT1day

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOduHT1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: ODU Severely Errored Seconds 1 Day Threshold

What is facilityDataThresholdSESOduHT1day?

This read-write OID defines the daily threshold for ODU Severely Errored Seconds accumulated across the full 24-hour measurement period. Crossing this threshold indicates persistent severe transmission quality problems that threaten service reliability and may require link rerouting or equipment replacement. An example configured value is 10 seconds, reflecting low tolerance for sustained severe error conditions.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOduHT1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOduHT1day.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.4.1 i <value>

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdSESOduHT1day OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.4facilityDataThresholdSESOduHT1dayADVA-FSPR7-PM-MIB