facilityDataThresholdESSHT15min

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdESSHT15min

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.65

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: Section / Regeneration Section Errored Seconds 15 Minute Threshold

What is facilityDataThresholdESSHT15min?

Reports a numeric threshold counter for errored seconds on regeneration section paths. This threshold monitors SONET section layer health and generates alerts when section-level transmission errors exceed acceptable rates during 15-minute intervals. Example value: 20 errored seconds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.65
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdESSHT15min

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.65.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdESSHT15min.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.65.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> facilityDataThresholdESSHT15min.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdESSHT15min OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.65facilityDataThresholdESSHT15minADVA-FSPR7-PM-MIB