ADVA-FSPR7-PM-MIB :: facilityDataThresholdESOtuHT1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityDataThresholdESOtuHT1day

facilityDataThresholdESOtuHT1day

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdESOtuHT1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.34

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: OTU Errored Seconds 1 Day Threshold

What is facilityDataThresholdESOtuHT1day?

This OID represents an unsigned integer threshold for errored seconds accumulated on the OTU layer across a complete 24-hour monitoring period. OTU error trends provide critical insights into long-term optical path health—when daily counts exceed this threshold, it indicates the optical infrastructure needs cleaning, alignment adjustment, or component replacement. An example threshold of 700 seconds per day would flag persistent optical quality issues affecting the transmission interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.34
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdESOtuHT1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.34.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdESOtuHT1day.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.34.1 i <value>

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdESOtuHT1day OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.34facilityDataThresholdESOtuHT1dayADVA-FSPR7-PM-MIB