ADVA-FSPR7-PM-MIB :: facilityDataThresholdBBEOtuHT1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityDataThresholdBBEOtuHT1day

facilityDataThresholdBBEOtuHT1day

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOtuHT1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.38

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-write

Description: OTU Background Block Errors 1 Day Threshold

What is facilityDataThresholdBBEOtuHT1day?

Reports an unsigned integer for the maximum daily accumulation of Background Block Errors on an OTU over 24 hours. This metric distinguishes temporary optical glitches from sustained link degradation requiring investigation. A typical threshold is 5000 background block errors per day.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.38
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOtuHT1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.38.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOtuHT1day.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.38.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> facilityDataThresholdBBEOtuHT1day.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOtuHT1day OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.38facilityDataThresholdBBEOtuHT1dayADVA-FSPR7-PM-MIB