All MIBs › ADVA-FSPR7-PM-MIB › facilityDataThresholdBBEOduHT1day
facilityDataThresholdBBEOduHT1day
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-write
Description: ODU Background Block Errors 1 Day Threshold
What is facilityDataThresholdBBEOduHT1day?
This read-write OID configures the daily threshold for ODU Background Block Errors measured over 24 hours, used to detect chronic transmission quality issues. Elevated background block error rates over extended periods may indicate optical impairments, fiber contamination, or component aging requiring maintenance intervention. A configured value might be 10000 blocks per day, representing acceptable baseline error tolerance.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6.1 i <value>
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.1 | pmFacilityDataThreshold | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.1.1 | facilityDataThresholdTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1 | facilityDataThresholdEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6 | facilityDataThresholdBBEOduHT1day | ADVA-FSPR7-PM-MIB |