ADVA-FSPR7-PM-MIB :: facilityDataThresholdBBEOduHT1day

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBfacilityDataThresholdBBEOduHT1day

facilityDataThresholdBBEOduHT1day

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-write

Description: ODU Background Block Errors 1 Day Threshold

What is facilityDataThresholdBBEOduHT1day?

This read-write OID configures the daily threshold for ODU Background Block Errors measured over 24 hours, used to detect chronic transmission quality issues. Elevated background block error rates over extended periods may indicate optical impairments, fiber contamination, or component aging requiring maintenance intervention. A configured value might be 10000 blocks per day, representing acceptable baseline error tolerance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6.1 i <value>

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::facilityDataThresholdBBEOduHT1day OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1pmFacilityDataThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1facilityDataThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1facilityDataThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.1.1.1.6facilityDataThresholdBBEOduHT1dayADVA-FSPR7-PM-MIB