ADVA-FSPR7-PM-MIB :: eqptPhysInstValueMaxOutProt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBeqptPhysInstValueMaxOutProt

eqptPhysInstValueMaxOutProt

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::eqptPhysInstValueMaxOutProt

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.1.2.1.1.1.9

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Sum of the equipment maximum power that can be protected for PSU failure

What is eqptPhysInstValueMaxOutProt?

Reports the total maximum output power that can still be supported by the equipment in the event of a single PSU failure. This read-only value indicates the shelf's power redundancy and fault-tolerance capacity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.1.2.1.1.1.9
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::eqptPhysInstValueMaxOutProt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.1.2.1.1.1.9.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::eqptPhysInstValueMaxOutProt.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::eqptPhysInstValueMaxOutProt OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1pmEqptADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2pmEqptPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.1pmEqptPhysValueADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.1.1eqptPhysInstValueTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.1.1.1eqptPhysInstValueEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.1.1.1.9eqptPhysInstValueMaxOutProtADVA-FSPR7-PM-MIB