All MIBs › ADVA-FSPR7-PM-MIB › dgdFacilityHistorical1weekValidFlag
dgdFacilityHistorical1weekValidFlag
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1weekValidFlag
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.47.1.5
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: Valid Flag
What is dgdFacilityHistorical1weekValidFlag?
Reports a boolean status indicating whether the entire 7-day DGD statistical collection is valid and free from measurement gaps, resets, or equipment faults. If this flag indicates invalid data, the mean and peak values cannot be reliably used for engineering decisions or trend analysis. A value of 'true' or '1' confirms continuous monitoring throughout the 7-day period with no collection interruptions.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.47.1.5 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1weekValidFlag
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.47.1.5.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1weekValidFlag.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1weekValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2 | pmFacilityPhysical | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3 | pmFacilityPhysRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.47 | dgdFacilityHistorical1weekTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.47.1 | dgdFacilityHistorical1weekEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.47.1.5 | dgdFacilityHistorical1weekValidFlag | ADVA-FSPR7-PM-MIB |