ADVA-FSPR7-PM-MIB :: dgdFacilityHistorical1dayValidFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBdgdFacilityHistorical1dayValidFlag

dgdFacilityHistorical1dayValidFlag

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayValidFlag

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.5

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Valid Flag

What is dgdFacilityHistorical1dayValidFlag?

Reports a boolean or enumerated value indicating whether the DGD statistical measurements for the 24-hour period are valid and reliable for analysis. This flag is set to false if the measurement interval was incomplete, interrupted, or if the monitoring equipment experienced faults during data collection. A value of '1' or 'true' confirms that all low/mean/high measurements from this day represent accurate facility performance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayValidFlag.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.45dgdFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1dgdFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.5dgdFacilityHistorical1dayValidFlagADVA-FSPR7-PM-MIB