All MIBs › ADVA-FSPR7-PM-MIB › dgdFacilityHistorical1dayMean
dgdFacilityHistorical1dayMean
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayMean
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.3
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Differential Group Delay Mean
What is dgdFacilityHistorical1dayMean?
Reports the average Differential Group Delay over a 24-hour collection period, expressed in picoseconds, showing the typical polarization-induced propagation time difference. This metric allows operators to assess the general optical path quality and predict when adaptive compensation adjustments may be required to maintain signal integrity. An example value might be 8.7 ps, indicating moderate dispersion characteristics typical for a mid-length optical circuit.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.3 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayMean
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.3.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayMean.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dgdFacilityHistorical1dayMean.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::dgdFacilityHistorical1dayMean OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2 | pmFacilityPhysical | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3 | pmFacilityPhysRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.45 | dgdFacilityHistorical1dayTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1 | dgdFacilityHistorical1dayEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.45.1.3 | dgdFacilityHistorical1dayMean | ADVA-FSPR7-PM-MIB |