All MIBs › ADVA-FSPR7-PM-MIB › checfrFacilityHistorical1dayTypeHecDiscardedFrames
checfrFacilityHistorical1dayTypeHecDiscardedFrames
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTypeHecDiscardedFrames
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.4
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Type Field HEC Discarded Frames
What is checfrFacilityHistorical1dayTypeHecDiscardedFrames?
This OID reports a counter of frames discarded due to uncorrectable Header Error Control errors in the type field during a 1-day collection interval. It indicates critical transmission failures where header corruption could not be recovered and frames had to be dropped. An example value is 3 to 12 discarded frames in a 24-hour period depending on link quality.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.4 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTypeHecDiscardedFrames
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.4.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTypeHecDiscardedFrames.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTypeHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.119 | checfrFacilityHistorical1dayTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1 | checfrFacilityHistorical1dayEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.4 | checfrFacilityHistorical1dayTypeHecDiscardedFrames | ADVA-FSPR7-PM-MIB |