ADVA-FSPR7-PM-MIB :: checfrFacilityHistorical1dayTimeStamp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBchecfrFacilityHistorical1dayTimeStamp

checfrFacilityHistorical1dayTimeStamp

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTimeStamp

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.6

Node type: OBJECT-TYPE

Type: DateAndTime

Access: read-only

Description: Timestamp

What is checfrFacilityHistorical1dayTimeStamp?

This OID reports a timestamp string or SNMP timeticks value marking the exact end time of the 1-day historical measurement collection period. It provides temporal context for performance archives and helps correlate daily statistics with other network events. An example value might be timeticks 4856372847 or a formatted timestamp like '2026-07-02 14:30:00'.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTimeStamp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTimeStamp.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> checfrFacilityHistorical1dayTimeStamp.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::checfrFacilityHistorical1dayTimeStamp OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.119checfrFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1checfrFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.119.1.6checfrFacilityHistorical1dayTimeStampADVA-FSPR7-PM-MIB