ADVA-FSPR7-PM-MIB :: cdFacilityHistorical1weekHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBcdFacilityHistorical1weekHigh

cdFacilityHistorical1weekHigh

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::cdFacilityHistorical1weekHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.53.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Chromatic Dispersion Compensation High

What is cdFacilityHistorical1weekHigh?

This OID reports an integer value representing the highest chromatic dispersion compensation measurement recorded during a one-week historical period. Operators monitor this to understand peak compensation demands and plan for capacity or fiber remediation needs. A typical value might be 187 indicating the maximum weekly CD compensation requirement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.53.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::cdFacilityHistorical1weekHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.53.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::cdFacilityHistorical1weekHigh.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cdFacilityHistorical1weekHigh.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::cdFacilityHistorical1weekHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.53cdFacilityHistorical1weekTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.53.1cdFacilityHistorical1weekEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.53.1.4cdFacilityHistorical1weekHighADVA-FSPR7-PM-MIB