ADVA-FSPR7-PM-MIB :: cdFacilityHistorical15minLow

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBcdFacilityHistorical15minLow

cdFacilityHistorical15minLow

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minLow

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Chromatic Dispersion Compensation Low

What is cdFacilityHistorical15minLow?

Reports the minimum Chromatic Dispersion compensation value in ps/nm (picoseconds per nanometer) measured over a 15-minute interval, showing the best optical channel condition. Chromatic dispersion accumulates along the fiber length and causes signal broadening; this metric tracks the actual compensation being applied to counteract it. A low value of 45 ps/nm indicates minimal accumulated dispersion requiring compensating adjustment during that interval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minLow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minLow.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minLow OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.49cdFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1cdFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.2cdFacilityHistorical15minLowADVA-FSPR7-PM-MIB