ADVA-FSPR7-PM-MIB :: cdFacilityHistorical15minHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBcdFacilityHistorical15minHigh

cdFacilityHistorical15minHigh

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Chromatic Dispersion Compensation High

What is cdFacilityHistorical15minHigh?

Reports the maximum Chromatic Dispersion compensation value in ps/nm during a 15-minute period, representing peak dispersion stress on the optical signal path. This high value indicates the worst-case dispersion condition encountered and guides the design of compensators and receiver equalization to handle worst-case scenarios. A peak of 512 ps/nm suggests occasional severe dispersion spikes requiring rapid compensator adjustment or indicating path anomalies.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minHigh.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cdFacilityHistorical15minHigh.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::cdFacilityHistorical15minHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.49cdFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1cdFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.49.1.4cdFacilityHistorical15minHighADVA-FSPR7-PM-MIB