Access: read-only

Description: Valid Flag

What is brTxOptMuxHistorical1dayValidFlag?

This object reports a Boolean/integer flag (0 or 1) indicating whether the daily backreflection power statistics collected at the transmit port are valid and trustworthy. In network monitoring, this flag is used to determine if the associated Low/Mean/High backreflection measurements should be considered reliable or if data collection issues occurred during the interval. A concrete example value would be 1 (true), indicating that the day's backreflection power samples are valid for analysis.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.3.3.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::brTxOptMuxHistorical1dayValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.3.3.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::brTxOptMuxHistorical1dayValidFlag.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::brTxOptMuxHistorical1dayValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17pmOptMuxADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2pmOptMuxPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3pmOptMuxPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.3brTxOptMuxHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.3.1brTxOptMuxHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.3.1.5brTxOptMuxHistorical1dayValidFlagADVA-FSPR7-PM-MIB