ADVA-FSPR7-PM-MIB :: atrcvDcnHistorical15minMean

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBatrcvDcnHistorical15minMean

atrcvDcnHistorical15minMean

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::atrcvDcnHistorical15minMean

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.2.2.3.19.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Mean Attenuation on Receive Fiber

What is atrcvDcnHistorical15minMean?

Reports a normalized integer value representing the average received signal attenuation during the 15-minute period, showing typical link performance. Monitoring the mean attenuation over time reveals gradual fiber aging, connector contamination, or misalignment—all factors that degrade optical path quality and eventually trigger alarms. A mean value of 20.2 dB represents nominal stable link performance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.2.2.3.19.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::atrcvDcnHistorical15minMean

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.2.2.3.19.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::atrcvDcnHistorical15minMean.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> atrcvDcnHistorical15minMean.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::atrcvDcnHistorical15minMean OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.2pmDcnADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.2.2pmDcnPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.2.2.3pmDcnPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.2.2.3.19atrcvDcnHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.2.2.3.19.1atrcvDcnHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.2.2.3.19.1.3atrcvDcnHistorical15minMeanADVA-FSPR7-PM-MIB