ADVA-FSPR7-PM-MIB :: atRcvOptMuxHistorical1weekHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBatRcvOptMuxHistorical1weekHigh

atRcvOptMuxHistorical1weekHigh

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::atRcvOptMuxHistorical1weekHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.17.2.3.17.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: High Attenuation on Receive Fiber

What is atRcvOptMuxHistorical1weekHigh?

Reports the peak attenuation value in dB recorded during the 1-week historical collection period. This metric helps identify temporary fiber stress events or environmental factors (temperature spikes, mechanical vibration) that cause momentary signal loss spikes above steady-state operation. Example: 12.3 dB represents an elevated peak attenuation occurrence during the week.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.3.17.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::atRcvOptMuxHistorical1weekHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.3.17.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::atRcvOptMuxHistorical1weekHigh.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::atRcvOptMuxHistorical1weekHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17pmOptMuxADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2pmOptMuxPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3pmOptMuxPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.17atRcvOptMuxHistorical1weekTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.17.1atRcvOptMuxHistorical1weekEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.17.1.4atRcvOptMuxHistorical1weekHighADVA-FSPR7-PM-MIB