ADVA-FSPR7-PM-MIB :: ampEqptHistorical15minLow

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBampEqptHistorical15minLow

ampEqptHistorical15minLow

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::ampEqptHistorical15minLow

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.1.2.3.1.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Board or Pluggable Submodule Low Current

What is ampEqptHistorical15minLow?

This read-only integer counter reports the minimum current draw (in milliamps) of an amplifier board or pluggable submodule measured during the most recent 15-minute interval. Network operators use this metric to identify power consumption dips and detect equipment malfunction or reduced workload states. A typical example value would be 450 mA indicating the lowest current draw during that interval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.1.2.3.1.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::ampEqptHistorical15minLow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.1.2.3.1.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::ampEqptHistorical15minLow.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::ampEqptHistorical15minLow OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1pmEqptADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2pmEqptPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.3pmEqptPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.3.1ampEqptHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.3.1.1ampEqptHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.1.2.3.1.1.2ampEqptHistorical15minLowADVA-FSPR7-PM-MIB