ADVA-FSPR7-MIB :: terminationPointOutputPower

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-MIBterminationPointOutputPower

terminationPointOutputPower

Module: ADVA-FSPR7-MIB

OID (symbolic): ADVA-FSPR7-MIB::terminationPointOutputPower

OID (numeric): 1.3.6.1.4.1.2544.1.11.7.7.1.1.1.13

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Termination Point Optical Power Tx.

What is terminationPointOutputPower?

Reports a GAUGE or INTEGER value in tenths of dBm representing the transmitted optical power from this port. Network operators monitor this to ensure laser power is within safe operating ranges and detect failing optical modules. Example value: -35 (representing -3.5 dBm) or 35 (3.5 dBm).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.7.1.1.1.13
snmpwalk -v2c -c public <target> ADVA-FSPR7-MIB::terminationPointOutputPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.7.1.1.1.13.1
snmpget -v2c -c public <target> ADVA-FSPR7-MIB::terminationPointOutputPower.1

Start monitoring ADVA (Adtran) FSP 3000 R7/R8 optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-MIB::terminationPointOutputPower OID value, configure state conditions and alerts, and monitor any ADVA (Adtran) FSP 3000 R7/R8 optical transport platform from a single console.

How to Use in IPNetwork Monitor

Select an ADVA (Adtran) FSP 3000 R7/R8 optical transport platform as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type terminationPointOutputPower into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the optical transmit (Tx) power at this termination point, in units of 0.1 dBm. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts outside the range expected for this transceiver, since an unexpected drop or spike in transmit power often indicates a failing laser. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.7advaFspR7ADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7featureSpecificADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1fiberMapADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1.1terminationPointTableADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1.1.1terminationPointEntryADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1.1.1.13terminationPointOutputPowerADVA-FSPR7-MIB