ADVA-FSPR7-MIB :: terminationPointInputPower

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-MIBterminationPointInputPower

terminationPointInputPower

Module: ADVA-FSPR7-MIB

OID (symbolic): ADVA-FSPR7-MIB::terminationPointInputPower

OID (numeric): 1.3.6.1.4.1.2544.1.11.7.7.1.1.1.14

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Termination Point Optical Power Rx.

What is terminationPointInputPower?

Reports a GAUGE or INTEGER value in tenths of dBm representing the received optical power at this port. Continuous monitoring enables early detection of fiber degradation, connector contamination, or equipment failure before service loss. Example value: -220 (representing -22.0 dBm) or -185 (-18.5 dBm).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.7.1.1.1.14
snmpwalk -v2c -c public <target> ADVA-FSPR7-MIB::terminationPointInputPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.7.1.1.1.14.1
snmpget -v2c -c public <target> ADVA-FSPR7-MIB::terminationPointInputPower.1

Start monitoring ADVA (Adtran) FSP 3000 R7/R8 optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-MIB::terminationPointInputPower OID value, configure state conditions and alerts, and monitor any ADVA (Adtran) FSP 3000 R7/R8 optical transport platform from a single console.

How to Use in IPNetwork Monitor

Select an ADVA (Adtran) FSP 3000 R7/R8 optical transport platform as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type terminationPointInputPower into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the optical receive (Rx) power at this termination point, in units of 0.1 dBm. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drops below the level expected for a healthy optical link, since falling receive power often precedes a fiber or connector problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.7advaFspR7ADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7featureSpecificADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1fiberMapADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1.1terminationPointTableADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1.1.1terminationPointEntryADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.7.1.1.1.14terminationPointInputPowerADVA-FSPR7-MIB