All MIBs › ADVA-FSPR7-MIB › pmSnapshotCurrentTerminPointInputPower
pmSnapshotCurrentTerminPointInputPower
Module: ADVA-FSPR7-MIB
OID (symbolic): ADVA-FSPR7-MIB::pmSnapshotCurrentTerminPointInputPower
OID (numeric): 1.3.6.1.4.1.2544.1.11.7.7.2.5.1.2
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description:
Total Optical Input Power Received.
What is pmSnapshotCurrentTerminPointInputPower?
This read-only object reports the total optical input power currently being received at the termination point of an optical interface, typically measured in dBm. It represents the signal strength of incoming optical signals on a port. An optical network technician would monitor this value to ensure ports are receiving adequate optical power and to detect signal degradation or fiber breaks.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.7.2.5.1.2 snmpwalk -v2c -c public <target> ADVA-FSPR7-MIB::pmSnapshotCurrentTerminPointInputPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.7.2.5.1.2.1 snmpget -v2c -c public <target> ADVA-FSPR7-MIB::pmSnapshotCurrentTerminPointInputPower.1
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11.7 | advaFspR7 | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7 | featureSpecific | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.2 | pmSnapshot | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.2.5 | pmSnapshotCurrentTerminPointTable | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.2.5.1 | pmSnapshotCurrentTerminPointEntry | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.2.5.1.2 | pmSnapshotCurrentTerminPointInputPower | ADVA-FSPR7-MIB |