ADVA-FSPR7-MIB :: physicalPortTimModeOtu

MIB Reference — IPNetwork Monitor

All MIBsADVA-FSPR7-MIBphysicalPortTimModeOtu

physicalPortTimModeOtu

Module: ADVA-FSPR7-MIB

OID (symbolic): ADVA-FSPR7-MIB::physicalPortTimModeOtu

OID (numeric): 1.3.6.1.4.1.2544.1.11.7.3.4.1.1.99

Node type: OBJECT-TYPE

Type: TimMode

Access: read-create

Description:

Detection of TIM-OTU Condition can be configured

What is physicalPortTimModeOtu?

Reports a boolean or enumerated value that enables or disables Tributary Unit Mismatch (TIM-OTU) alarm detection on the OTU signal. Monitors OTU overhead trace identifier mismatches to validate that the correct tributary is mapped to this port and detect signal cross-connection errors. Example: enabled to actively detect and alarm when OTU trace identifier does not match the configured path.

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
1.3.6.1.4.1.2544.1.11.7advaFspR7ADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.3managementADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.3.4facilityMgmtADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.3.4.1physicalPortTableADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.3.4.1.1physicalPortEntryADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.3.4.1.1.99physicalPortTimModeOtuADVA-FSPR7-MIB