ADVA-FSPR7-MIB :: optIntervalPm15minValidFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-MIBoptIntervalPm15minValidFlag

optIntervalPm15minValidFlag

Module: ADVA-FSPR7-MIB

OID (symbolic): ADVA-FSPR7-MIB::optIntervalPm15minValidFlag

OID (numeric): 1.3.6.1.4.1.2544.1.11.7.6.4.2.1.1.5

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Valid Flag

What is optIntervalPm15minValidFlag?

This read-only boolean object indicates whether the optical performance monitoring (PM) counters collected during the most recent 15-minute interval on an ADVA FSP3000 optical interface are valid and accurate. When true, the PM statistics in the preceding 15-minute bucket meet data quality requirements; when false, the data should not be used for statistical analysis or threshold crossing detection. Optical network operators rely on this flag to determine when performance reports are complete and reliable for SLA (Service Level Agreement) calculations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.6.4.2.1.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-MIB::optIntervalPm15minValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.7.6.4.2.1.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-MIB::optIntervalPm15minValidFlag.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> optIntervalPm15minValidFlag.1

Start monitoring ADVA (Adtran) FSP 3000 R7/R8 optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-MIB::optIntervalPm15minValidFlag OID value, configure state conditions and alerts, and monitor any ADVA (Adtran) FSP 3000 R7/R8 optical transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.7advaFspR7ADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.6performanceADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.6.4performanceFacilityADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.6.4.2performanceFacilityMonitoringADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.6.4.2.1optIntervalPm15minTableADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.6.4.2.1.1optIntervalPm15minEntryADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.6.4.2.1.1.5optIntervalPm15minValidFlagADVA-FSPR7-MIB