All MIBs › ADVA-FSPR7-MIB › externalPortFecType
externalPortFecType
Module: ADVA-FSPR7-MIB
OID (symbolic): ADVA-FSPR7-MIB::externalPortFecType
OID (numeric): 1.3.6.1.4.1.2544.1.11.7.7.3.1.1.9
Node type: OBJECT-TYPE
Type: FspR7FecType
Access: read-create
Description:
Forward Error Correction (Only relevant where TYPE = OTU#)
What is externalPortFecType?
Identifies the Forward Error Correction algorithm applied to this external port (e.g., Reed-Solomon RS(255,239), GFEC, UFEC, SDFEC). FEC choice directly impacts latency, overhead, and noise tolerance; different bitrates and distances require different FEC strengths. Example: externalPortFecType = 'UFEC' (Ultra FEC) indicates an aggressive error correction scheme suitable for 200+ km terrestrial links with high noise environments.
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11.7 | advaFspR7 | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7 | featureSpecific | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.3 | eci | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.3.1 | externalPortTable | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.3.1.1 | externalPortEntry | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.3.1.1.9 | externalPortFecType | ADVA-FSPR7-MIB |