All MIBs › ADVA-FSPR7-MIB › changePhysicalPortServiceTcmCLevel
changePhysicalPortServiceTcmCLevel
Module: ADVA-FSPR7-MIB
OID (symbolic): ADVA-FSPR7-MIB::changePhysicalPortServiceTcmCLevel
OID (numeric): 1.3.6.1.4.1.2544.1.11.7.7.5.1.1.50
Node type: OBJECT-TYPE
Type: OtnTcmLevel
Access: read-create
Description:
Activation of Tandem Connection Monitoring Instance C
What is changePhysicalPortServiceTcmCLevel?
This object enables or configures Tandem Connection Monitoring (TCM) at level C, which is a diagnostic feature for OTN (Optical Transport Network) services on physical ports. TCM monitors the integrity of path segments in the optical signal hierarchy and reports performance degradation. An operator would enable this when detailed path-level monitoring of optical transport is needed for troubleshooting or SLA verification.
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11.7 | advaFspR7 | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7 | featureSpecific | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.5 | changeService | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.5.1 | changePhysicalPortServiceTable | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.5.1.1 | changePhysicalPortServiceEntry | ADVA-FSPR7-MIB |
| 1.3.6.1.4.1.2544.1.11.7.7.5.1.1.50 | changePhysicalPortServiceTcmCLevel | ADVA-FSPR7-MIB |