ADVA-FSPR7-MIB :: alarmThres15MinExceededOduTcmBBbe

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-MIBalarmThres15MinExceededOduTcmBBbe

alarmThres15MinExceededOduTcmBBbe

Module: ADVA-FSPR7-MIB

OID (symbolic): ADVA-FSPR7-MIB::alarmThres15MinExceededOduTcmBBbe

OID (numeric): 1.3.6.1.4.1.2544.1.11.7.5.0.287

Node type: NOTIFICATION-TYPE

Description: Background Block Errors ODU Tandem Connection Monitoring

What is alarmThres15MinExceededOduTcmBBbe?

This OID is an alarm notification that fires when the count of Background Block Errors on an ODU (Optical Data Unit) at Tandem Connection Monitoring level exceeds the threshold set for a 15-minute interval. Background Block Errors indicate bit corruption in the optical signal, signaling degrading fiber quality. An optical network operator would receive this alarm to investigate and replace failing fiber spans or optics before the link becomes completely unusable.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' ADVA-FSPR7-MIB::alarmThres15MinExceededOduTcmBBbe
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.2544.1.11.7.5.0.287

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:52374->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (252912790) 29 days, 6:32:07.90
  SNMPv2-MIB::snmpTrapOID.0 = OID: ADVA-FSPR7-MIB::alarmThres15MinExceededOduTcmBBbe

SNMPv3 example:

snmptrap -v3 -l authPriv -u snmpv3user -a SHA -A "AuthPass1" -x AES -X "PrivPass1" <manager> '' ADVA-FSPR7-MIB::alarmThres15MinExceededOduTcmBBbe

Start monitoring ADVA (Adtran) FSP 3000 R7/R8 optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-MIB::alarmThres15MinExceededOduTcmBBbe OID value, configure state conditions and alerts, and monitor any ADVA (Adtran) FSP 3000 R7/R8 optical transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.7advaFspR7ADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.5trapADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.5.0fspR7TrapADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.5.0.287alarmThres15MinExceededOduTcmBBbeADVA-FSPR7-MIB