ADVA-FSPR7-MIB :: alarmInputVoltageFailure

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-MIBalarmInputVoltageFailure

alarmInputVoltageFailure

Module: ADVA-FSPR7-MIB

OID (symbolic): ADVA-FSPR7-MIB::alarmInputVoltageFailure

OID (numeric): 1.3.6.1.4.1.2544.1.11.7.5.0.401

Node type: NOTIFICATION-TYPE

Description: Failure of Input Voltage

What is alarmInputVoltageFailure?

A notification event triggered when input power supply voltage drops below acceptable levels. This alert indicates the device is losing primary AC power or the power supply is failing. Use this alarm to trigger immediate response when backup power or power supply replacement is needed.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' ADVA-FSPR7-MIB::alarmInputVoltageFailure
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.2544.1.11.7.5.0.401

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:57113->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (272550169) 31 days, 13:05:01.69
  SNMPv2-MIB::snmpTrapOID.0 = OID: ADVA-FSPR7-MIB::alarmInputVoltageFailure

Start monitoring ADVA (Adtran) FSP 3000 R7/R8 optical transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-MIB::alarmInputVoltageFailure OID value, configure state conditions and alerts, and monitor any ADVA (Adtran) FSP 3000 R7/R8 optical transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.7advaFspR7ADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.5trapADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.5.0fspR7TrapADVA-FSPR7-MIB
1.3.6.1.4.1.2544.1.11.7.5.0.401alarmInputVoltageFailureADVA-FSPR7-MIB